TECHNICAL DATA
Measuring fields:
CO from 0 to 9.99 %vol Res. 0.01
CO2 from 0 to 19.9 %vol Heat. 0.1
HChexane from 0 to 19999 ppmvol Heat. 1
02 from 0 to 25 %vol Res. 0.01
No from 0 to 5000 %vol Res 1
Lambda from 0.5 to 5 Res. 0.001
Revs (induction/capacitive) from 300 to 19990 revs/min Res. 10
Oil from 20 to 150 ºC Res. 1
Measuring chamber: AMB 2
Measuring Gas suction sensors 4 l/min. (6-m connection to gas probe)
Automatic and continuous condensate drainage
Semiautomatic tightness test with manual closure of the sampling probe
Automatic control of minimum flow
Automatic control of spent O2 sensor (up to 5mV and from 7mV)
Filters protecting cylinder-heads from water/gas from the pump placed externally in order to avoid having to open the device removing the seals
Automatic compensation of Ambient Pressure from 85,0 to 106,0 KPa
Calibration with sample gas bottle
Automatic autozero
Heating time to 20ºC: 10 minutes maximum
Response time CO, CO2 e HC < 15 sec
CONNECTIONS
RPM acquisition via wire from induction clip or capacitive clip
Oil temperature input from PT100 probe (DIN43760)
Rpm/oil temperature reception via RS-232 wire, optional 433MHz radio
Serial connections: PC USB B (slave mode); PC RS-232 (9600,8,N,1); PC in RS-485 network (9600,8,N,1)
Software programming / update via RS-232 wire
Possibility to become operator interface towards opacimeter OPA-100
Integrated 24-column thermal printer
Typical 12 VDC power supply (11-15 VDC)
Consumption 1.5° DC (3A printing the test report)
Operating temperature from 5 to 40°C
Dimensions 434X190X291 mm
Weight 5Kg (estimated weight)
1 – Are the Analyzers and Smokemeters MCTCNET2-type approved?
All of the Brain Bee analyzers and smokemeters will be MCTCNET 2 – type approved as soon as the Ministry will be able to do it (probably not before October 2010). New tools will be released with MCTCNET 2 type-approval, while the tools sold earlier will have to be fitted with a hardware key and a new software. Costs will be in any case quite low.
2 – Can the gas line be interfaced with Bluetooth?
Yes, in several ways, in any case always with the introduction of the Bluetooth BT100 modules. A tool configuration with PS170 supplier module is also available making the whole setup completely independent and wireless.
3 – Does it require special maintenance?
The manufacturing quality and the selection of materials give Brain Bee tools excellent operating reliability.
Ask a Question Form
Description
OFFICIAL VEHICLE INSPECTION TESTS AND FOR BLUE QUALITY-GUARANTEE STICKER
In accordance with Decreto DM/628 and successive circulars, AGS-200 enables you to carry out the official test in the vehicle inspection procedure.
EASY TO USE
- INTUITIVE KEYPAD
- 6 LIQUID CRYSTAL DISPLAY UNITS
- INCORPORATES A PRINTER
- CONNECTABLE TO ANY PC, for operation using BRAIN BEE’s OMNIBUS800 software
THE PNEUMATIC GROUP
The innovative Condensate Separator Group is drop-forged in order to minimise gas travel and reduce maintenance times. Its design facilitates the continuous draining of the condensate water that forms in the separator. AUTOZERO and CALIBRATION with sample gas
INTEGRATABLE WITH BRAIN BEE ACCESSORIES AND INSTRUMENTS
Designed as a basic exhaust gas analyser, with its array of connectable optional accessories it can carry out other functions.
CERTIFICATION
– Conforms to ISO 3930/OIML class 0
– MID 2004/22/CE
– DM 628/96 and successive circulars
– AU 4 (Germany)
– MOT (UK)
– Austria
– PCT-Gosstandart of Russia (Russia)
– BRML (Romania)
– OMH (Hungary)
– Bulgaria
– Czech Republic
– ARAI (India)
Conforms to the MCTCNET communication protocol
Metrological Book included